Nematron OptiLogic Series Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Akcesoria komputerowe Nematron OptiLogic Series. Nematron OptiLogic Series User Manual [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Input/Output Modules

Optimation, Inc.(256)883-3050 1www.optimate.comOptiLogic SeriesOptiLogicInput/Output ModulesOptimal Automation for Industry

Strona 2 - Trademarks

Optimation, Inc.(256)883-305010www.optimate.comOptiLogic SeriesTransistor OutputsNPN Transistor Sinking OutputsAn NPN transistor sinking outputpro

Strona 3 - Table of Contents

Optimation, Inc.(256)883-3050 11www.optimate.comOptiLogic SeriesAnalog InputsAnalog inputs are used to monitor thevalue of some continuously

Strona 4

Optimation, Inc.(256)883-305012www.optimate.comOptiLogic SeriesResolutionResolution is the number of significantbits of information the A/D conve

Strona 5

Optimation, Inc.(256)883-3050 13www.optimate.comOptiLogic SeriesSingle Ended InputsSingle ended inputs are all referenced tothe same ground point. In

Strona 6 - Introduction

www.optimate.com Terminal Terminal 1 Out0 NO 5 Out2 NO 2 Out0 C 6 Out2 C 7 OL2104 Relay Output Module Outputs 4 Card Ca

Strona 7 - Digital Inputs

www.optimate.com Terminal Terminal 1 Common Out 0-3 6 Out 3 2 Common Out 4-7 7 Out 4 3 Out 0 8 Out 5 4 Out 1 9 Ou

Strona 8 - I/O “Common” Terminals

Optimation, Inc.(256)883-305016www.optimate.comOptiLogic SeriesOL2109 DC Sinking Output ModuleOutputs 8Card Cage Powerrequired140 mAOutput TypeNPN ope

Strona 9 - Digital Outputs

Optimation, Inc.(256)883-3050 17www.optimate.comOptiLogic SeriesOL2111 AC Solid State Relay ModuleOutputs 8Card Cage Powerrequired120 mAOutput Type SS

Strona 10 - Solid State Relay Outputs

Optimation, Inc.(256)883-305018www.optimate.comOptiLogic SeriesOL2201 Digital Input Simulator ModuleInputs 8Card Cage PowerRequired60mAInput Type Togg

Strona 11 - Analog Inputs

Optimation, Inc.(256)883-3050 19www.optimate.comOptiLogic SeriesOL2205 AC/DC Input ModuleInputs 4Card Cage PowerRequired60mAInput Type AC Optocoupled

Strona 12 - Bits of Resolution

Optimation, Inc.(256)883-30502www.optimate.comOptiLogic SeriesWARNINGThank you for purchasing industrial control products from Optimation, Inc. We wa

Strona 13 - Differential Inputs

Optimation, Inc.(256)883-305020www.optimate.comOptiLogic SeriesOL2208 DC Digital Input ModuleInputs 8Card Cage Powerrequired60mAInput Type DC Optocoup

Strona 14 - Required Temperature

Optimation, Inc.(256)883-3050 21www.optimate.comOptiLogic SeriesOL2211 AC Digital Input ModuleInputs 8Card Cage PowerRequired60 mAInput Type AC Optoc

Strona 15

Optimation, Inc.(256)883-305022www.optimate.comOptiLogic SeriesOL2252 Dual High Speed Pulse CounterInputs (all) 8Card Cage PowerRequired100 mAPulse In

Strona 16 - Optimation, Inc

Optimation, Inc.(256)883-3050 23www.optimate.comOptiLogic SeriesOL2252 Dual Pulse Counter cont’dThe OL2252 Dual Pulse input module isdesigned to pro

Strona 17 - Required Temperature

Optimation, Inc.(256)883-305024www.optimate.comOptiLogic SeriesOL2252 Pulse Input cont’dInput SignalThe input pulse train is a repetitivesquare

Strona 18 - (256)883-3050

Optimation, Inc.(256)883-3050 25www.optimate.comOptiLogic SeriesOL2258 High Speed Pulse CounterInputs (all) 4Card Cage PowerRequired100 mAPulse Inputs

Strona 19

Optimation, Inc.(256)883-305026www.optimate.comOptiLogic SeriesOL2258 High Speed Pulse Counter cont’dInterfacing the OL2258The OL2258 High Speed Pulse

Strona 20

Optimation, Inc.(256)883-3050 27www.optimate.comOptiLogic SeriesOL2258 High Speed Pulse Counter cont’dPulse and DirectionIn this configuration, pulses

Strona 21

Optimation, Inc.(256)883-305028www.optimate.comOptiLogic SeriesOL2304 Four Channel Voltage OutputOutputs 4Card Cage Powerrequired700mAOutput Ranges0-5

Strona 22

Optimation, Inc.(256)883-3050 29www.optimate.comOptiLogic SeriesOL2408 Analog Voltage Input ModuleInputs 8 Power required 700mAInput Type0-5 VDC or0-1

Strona 23

Table of ContentsIntroduction . . . . . . . . 6Digital Inputs . . . . . . . . 7Input Isolation . . . . . . . 7DC Inputs . . . . . . . . 7AC Inputs . .

Strona 24 - OL2252 Pulse Input cont’d

Optimation, Inc.(256)883-305030www.optimate.comOptiLogic SeriesOL2418 Analog Current Input ModuleInputs 8Card Cage PowerRequired700mAInput Type 4 - 20

Strona 25

Optimation, Inc.(256)883-3050 31www.optimate.comOptiLogic SeriesOL2602 Dual RS232 ModuleCommunication Ports 2Card Cage PowerRequired110 mAType RS232C

Strona 26 - (Bipolar differential)

Optimation, Inc.(256)883-305032www.optimate.comOptiLogic Series

Strona 27 - 1 2 3 4 5 4 3

OL2602 Dual RS232 Module . . . . . 31Optimation, Inc.(256)883-30504www.optimate.comOptiLogic Series

Strona 28

www.optimate.com Revision History Issue Date Pages Description Original 8/99 1-24 Original release 1.1 1/00 13, 18, 25 Added OL2104,

Strona 29 - Offset Calibration error

Optimation, Inc.(256)883-30506www.optimate.comOptiLogic SeriesOptiLogic Input/Output ModulesIntroductionOptimation’s OptiLogic series is aflexible

Strona 30 - Offset Calibration Error

Optimation, Inc.(256)883-3050 7www.optimate.comOptiLogic SeriesDigital InputsDigital I/O modules are used to eithermonitor (input) or control (o

Strona 31

Optimation, Inc.(256)883-30508www.optimate.comOptiLogic SeriesAC InputsAC digital inputs are typically suppliedeither directly from line voltage or tr

Strona 32

Optimation, Inc.(256)883-3050 9www.optimate.comOptiLogic SeriesDigital OutputsDigital outputs are used to turn “loads”on and off. “Loads” may b

Komentarze do niniejszej Instrukcji

Brak uwag